N3000 NAS
Specifications | |||||||||
---|---|---|---|---|---|---|---|---|---|
N3300 | N3300 | N3400 series | N3400 series | N3600 | |||||
Machine Type Model | 2859-A10 | 2859-A20 | 2859-A11 | 2859-A21 | 2862-A20 | ||||
Controller configuration | Single | Dual (active/ active) | Single | Dual (active/ active) | Dual (active/ active) | ||||
Processors Speed and Type | style="font-weight: lighter;" class="small">Intel 2.2 GHz Mobile Celeron | style="font-weight: lighter;" class="small">Intel 1.66 GHz Mobile Celeron |
style="font-weight: lighter;" class="small">Intel 2.2 GHz Mobile Celeron | ||||||
Number of Processors | 1 | 2 | 2 | 4 | 2 | ||||
Random Access Memory | 1 GB | 1 GB | 4 GB | 8 GB | 4 GB | ||||
Nonvolatile memory | 128 MB | 256 MB | 256 MB | 512 MB | 512 MB | ||||
Integrated I/O Ports | |||||||||
Fibre Channel Ports (Speed) | 2 (4 Gbps) | 4 (4 Gbps) | 2 (4-Gbps) | 4 (4-Gbps) | 4(4 Gbps) | ||||
Ethernet Ports (Speed) | 2 (1 Gbps) | 4 (1 Gbps) | 4 (1-Gbps) | 8 (1-Gbps) | 4 (1 Gbps) | ||||
Storage Scalability | |||||||||
Maximum Number of Fibre Channel Loops | 1 | 1 | 1 | 1 | 2 | ||||
Maximum Raw Capacity (Note 3) | 68 TB | 68 TB | 136 TB | 136 TB | 104 TB | ||||
Maximum Number of Internal Drives | 12 | 12 | 12 | 12 | 20 | ||||
Maximum Number of Expansion Drives | 56 | 56 | 124 | 124 | 84 | ||||
Maximum Number of Disk Drives | 68 | 68 | 136 | 136 | 104 | ||||
Maximum Volume Size | 16 TB | 16 TB | 16 TB | 16 TB | 16 TB | ||||
Maximum size of Volumes/LUNs | 1024 | 1024 | 1024 | 1024 | 1024 | ||||
Maximum Number of Storage Enclosures | 4 | 4 | 6 FC 5 SAS |
6 FC 5 SAS |
6 | ||||
Maximum Number of ports per controller configured as front-end (host) connectivity ports | 2 | ||||||||
Maximum Number of directly connected servers (per controller and per active/active configuration) | 4 | ||||||||
Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) | 24 | ||||||||
Disk Drives Supported in Controller (size, type, speed) | SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 500 GB, 7,200 rpm; 1 TB |
SAS: 300 GB, 450 GB, 600 GB 15,000 rpm SATA: 500 GB, 7,200 rpm; 1 TB |
SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 1 TB |
||||||
Disk Expansion Units Supported | EXN4000 - Fibre Channel Disk Storage Expansion Unit: 4-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB 15,000 rpm 2-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB 15,000 rpm EXN1000 - SATA Disk Storage Expansion Unit: SATA: 500 GB, 7,200 rpm; 1 TB |
EXN4000 - Fibre Channel Disk Storage Expansion Unit: 4-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm 2-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm EXN3000 - SAS Disk Storage Expansion Unit: SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 500 GB, 7,200 rpm; 1 TB EXN1000 - SATA Disk Storage Expansion Unit: SATA: 500 GB, 7,200 rpm; 1 TB |
EXN4000 - Fibre Channel Disk Storage Expansion Unit: 4-Gbps, 2-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm EXN3000 - SAS Disk Storage Expansion Unit: SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 1 TB EXN1000 - SATA Disk Storage Expansion Unit: SATA: 1 TB |
||||||
I/O Scalability | |||||||||
PCI-Express (PCI-e) Expansion Slots | 0 | 0 | 0 | 0 | 2 | ||||
Maximum number of FC Ports | 2 | 4 | 2 | 4 | 12 | ||||
Maximum number of SAS Ports | 0 | 0 | 1 | 2 | 0 | ||||
Maximum number of Ethernet Ports | 2 | 4 | 4 | 8 | 8 | ||||
Maximum Number of Optional Adapters | 0 | 0 | 0 | 0 | 2 | ||||
Maximum Number of Adapters Supported Per System (belownot to exceed Maximum Number of Optional Adapters) | |||||||||
1012 - Dual-port Gigabit Ethernet adapter (optical) | - | - | - | - | 2 | ||||
1013 - Dual-port Gigabit Ethernet adapter (copper) | - | - | - | - | 2 | ||||
1014 - Dual-port 4 Gbps FC HBA for Disk Attachment | - | - | - | - | 2 | ||||
1015 - Dual-port 4 Gbps FC HBA for Tape Attachment | - | - | - | - | 2 | ||||
1021 - Dual-port GbE iSCSI Target (optical) | - | - | - | - | 2 | ||||
1023 - Quad-port Gigabit Ethernet (copper) | - | - | - | - | 2 | ||||
1024 - PCIe U-SCSI 320 Tape | - | - | - | - | 2 | ||||
1026 - PCIe Dual-port SCSI Copper | - | - | - | - | 2 | ||||
1029 - Quad-port 4 Gbps FC HBA for Disk/Tape | - | - | - | - | 2 | ||||
1030 - Quad port 4 Gbps FC Target | - | - | - | - | 2 | ||||
1033 - SnapMirror over FC HBA | - | - | - | - | 2 | ||||
1036 - PCIe 2 port 8 Gb FC Target HBA | - | - | - | - | 2 | ||||
1060 - Dual-port mini-SAS adapter for Disk Attachment | - | - | - | - | 2 | ||||
1062 - 10 Gbps Ethernet NIC card | - | - | - | - | 2 | ||||
1063 - Dual-port FCoE adapter (optical) | - | - | - | - | 2 | ||||
1064 - Dual-port FCoE adapter (cooper) | - | - | - | - | 2 | ||||
Environmental specifications | |||||||||
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240 V ac, 10 to 4 A, 50/60 Hz, 675 W | 100 to 240 V ac, 12 to 5A, 50/60 Hz, 855 W | |||||||
Thermal rating | 1560 Btu/hr (note: Watts x 3.4129) | 1928 Btu/hr | |||||||
Weight (max.) | 64 lb (28 kg) | 66 lb (30 kg) | 64 lb (28 kg) | 66 lb (30 kg) | 112 lb (51 kg) | ||||
Height | 3.45" (8.75 cm), fits into 2U space | 6.95" (17.75 cm), fits into 4U space | |||||||
Width | 19" IEC rack-compliant (17.7", 44.9 cm) | ||||||||
Depth | 22" (56 cm) | ||||||||
Operating temperature, altitude, and relative humidity | 10C to 40C (50F to 104F); at = 3,000 m (at = 10,000 ft) elevation; 20% to 80% relative humidity, noncondensing (28C wet bulb temperature)|||||||||
Nonoperating temperature and relative humidity | -40C to 60C (-40F to 140F); 10% to 95% relative humidity, noncondensing, in original container </=54 dBA sound pressure (LpA) @ normal operating conditions (at 23C and at sea level) |
||||||||
Operating acoustic noise | 25.4 cm (10") in front, 30.5 cm (12") in rear | ||||||||
Min. cabinet clearances | 76.2 cm (30") in front, 76.2 cm (30") in rear | ||||||||
Min. service clearances | 10,000 ft (3050 m) | ||||||||
Maximum altitude | |||||||||
Regulations | |||||||||
Filer safety | EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R, | ||||||||
Disk shelf safety | BSMI CNS14336, CCC GB 4943-2001, SABS, S Resolution 92-98 | ||||||||
Emissions/ Immunity | UL/C-UL; CE FCC Part 15 Class A, ICES-003, CE, MIC, VCCI, AS/NZS EN55022, EN55024, IEC61000-3-2, IEC61000-3-3, BSMI, KN22, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, KN24, CISPR 24 |
||||||||
Storage Expansion Unit Disk Drive Support | |||||||||
EXN4000 - 4 Gbps Fibre Channel disk storage expansion unit (MTM 2863-004) | 4, 2 Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm | ||||||||
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003)* | SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 500 GB**, 7,200 rpm; 1 TB |
||||||||
EXN1000 - SATA disk storage expansion unit (MTM 2861-001) | SATA: 500 GB**, 7,200 rpm; 1 TB | ||||||||
Storage Expansion Unit Specifications | |||||||||
Disk Storage expansion units supported | EXN4000 - 4 Gbps Fibre Channel Disk storage expansion unit (MTM 2863-004) EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003)* EXN1000 SATA disk storage expansion unit (MTM 2861-001) EXN4000 and EXN1000 each with 14 low-profile slots for fibre channel and SATA disk drives EXN3000 with 24 slots for SAS and SATA disk drives Legacy support for expansion unit |
||||||||
Disk drive storage shelf interface | PCI-x or PCI-e-based Fibre Channel-Arbitrated Loop (FC-AL) | ||||||||
Environmental specifications | |||||||||
Power supply/cooling fans | Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V) | ||||||||
AC power/max. current | 100 to 120 V ac/4.4A; 200 to 240 V ac/2.3A 100 to 120 V ac/7A; 200-240 V ac/3.5A; 50/60 Hz | ||||||||
Operating temperature maximum range | 10C to 40C (50F to 104F) | ||||||||
Recommended operating temperature range | 20C to 25C (68F to 77F) | ||||||||
Operating relative humidity range | 10% to 95% relative humidity, noncondensing 10% to 95% | ||||||||
Recommended operating relative humidity range | 40% to 55% noncondensing | ||||||||
Nonoperating temperature range | -40C to 65C (-40F to 149F) | ||||||||
Nonoperating relative humidity range | 10% to 95% relative humidity, noncondensing | ||||||||
Thermal rating | 1,215 Btu/hr (fully loaded disk storage expansion unit) | ||||||||
Operating acoustic noise | 56.4 dBA @ 1 m at 23C, 5.64 bels @ 23C | ||||||||
Dimensions (height/width/depth) | EXN4000 and EXN1000 3U EIA (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.8 cm) EXN3000 4U EIA (6.9, 17.49 cm)/19 IEC rack-compliant (17.7", 44.87 cm) / 25.7" (65.35 cm) |
||||||||
Weight | EXN4000 35.8 kg (78.8 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty EXN3000 110 lb (49.9 kg) fully loaded with disk drives, 53.7 lbs (24.4 kb) empty EXN1000 35 kg (77 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty |
||||||||
Regulations | |||||||||
Disk shelf safety | UL/C-UL; CE | ||||||||
Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI | ||||||||
Immunity | EN 55024:1998 | ||||||||
IBM System Storage N3000 Express series Technical Specifications | |||||||||
Technical Highlights | |||||||||
Maximum RAID Group Sizes | RAID-6 (RAID-DP) FC28 (26 data disks plus 2 parity disks) SATA16 (14 data disks plus 2 parity disks) RAID-41 FC14 (13 data disks plus 1 parity disk) SATA7 (6 data disks plus 1 parity disk) |
||||||||
SAN Protocol Support | Fibre Channel Protocol (FCP) and/or iSCSI; fabric-attached and direct-attached | ||||||||
Network Protocol Support | NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS, HTTP 1.0, HTTP 1.1 virtual hosts, FTP | ||||||||
FlexVols | Up to 500 per controller | ||||||||
Snapshots | Up to 127,000 per controller | ||||||||
Reliability | Redundant hot-swappable controllers, cooling fans and power supplies | ||||||||
Management | Full-duplex 10/100 Base-T Ethernet onboard console, diagnostic LED, Maintenance Center, SNMP, telnet, SSH, HTTP, Web, e-mail alerts, Operations Manager, Protection Manager | ||||||||
Security | Virus Protection, SecureAdmin, IPSec, CHAP authentication, Role Based access control (RBAC) |
* Not supported by N3300 series
** 500 GB not supported by N3600 series
1 RAID-6 is the recommended configuration for drives greater than 144 GB.