System Storage N series Gateway for SAN Storage Environments
Specifications | ||||||||
---|---|---|---|---|---|---|---|---|
N7900 | ||||||||
Machine type model | 2867-A21 | |||||||
Gateway Machine Type Model | 2867-A21 (w/FC 9551) | |||||||
Controller Configuration | Dual (active/active) | |||||||
Processors Speed and Type | 2.6 GHz AMD Dual-core Opteron | |||||||
Number of Processors | 8 | |||||||
Random Access Memory | 64 GB | |||||||
Nonvolatile Memory | 4 GB | |||||||
Integrated I/O Ports | ||||||||
Fibre Channel Ports/Speed | 16 (4-Gbps) | |||||||
Ethernet Ports/Speed | 12 (1-Gbps) | |||||||
Storage Scalability | ||||||||
Maximum Number of Fibre Channel Loops | 14 | |||||||
Maximum Raw Capacity | 1176 TB | |||||||
Maximum Number of Disk Drives | 1176 | |||||||
Maximum Volume Size | 16 TB | |||||||
Maximum Number of Volumes/LUNs | 2048 | |||||||
Maximum Number of Storage Enclosures | 84 | |||||||
Disk Expansion Units Supported | EXN4000 - Fibre Channel Disk Storage Expansion Unit EXN3000 - SAS Disk Storage Expansion EXN1000 - SATA Disk Storage Expansion |
|||||||
I/O Scalability | ||||||||
PCI-Express (PCI-e) Expansion Slots | 10 | |||||||
PCI-x Expansion Slots | 6 | |||||||
Maximum Number FC ports | 56 | |||||||
Maximum Number of Ethernet ports | 52 | |||||||
Maximum Number of Adapters Supported Per System (belownot to exceed Maximum Number of Optional Adapters) | ||||||||
1007 - Quad-Port GbE NIC (copper) | 4 | |||||||
1008 - Single-Port 10-GbE Toe NIC | 4 | |||||||
1009 - Quad-Port GbE TOE NIC (copper) | 4 | |||||||
1010 - Dual-Port iSCSI Target NIC (copper) | 6 | |||||||
1011 - Dual-Port iSCSI Target NIC (fibre) | 6 | |||||||
1012 - Dual-Port GbE NIC (fibre) | 10 | |||||||
1013 - Dual-Port GbE NIC (copper) | 10 | |||||||
1014 - Dual-Port 4-Gbps FC HBA Disk | 10 | |||||||
1015 - Dual-Port 4-Gbps FC HBA Tape | 6 | |||||||
1016 - SCSI LVD Tape Adapter | 6 | |||||||
1017 - Dual-Port 4-Gbps FC HBA Target | N/A | |||||||
1021 - Dual-Port GbE iSCSI Target (fibre) | 10 | |||||||
1022 - Quad-Port GbE TOE NIC (copper) | 10 | |||||||
1023 - Quad-Port GbE NIC (copper) | 10 | |||||||
1024 - Dual-Port SCSI Ultra320 HBA Tape | 6 | |||||||
1026 - Dual-Port GbE NIC (copper) | 10 | |||||||
1029 - Quad-Port 4-Gbps FC HBA DISK | 10 | |||||||
1030 - Quad port 4-Gbps FC Target | 8 | |||||||
1031 - Dual-Port 10-GbE TOE NIC | 10 | |||||||
1032 - Dual-Port MetroCluster VI HBA | 4 | |||||||
1033 - SnapMirror Over FC HBA PCI-e | 4 | |||||||
1034 - SnapMirror Over FC HBA PCI-x | 4 | |||||||
1035 - Quad-Port 4-GBPS FC HBA Tape/Disk | 10 | |||||||
1036 - PCIe 2 port 8 Gb FC Target HBA | 10 | |||||||
1056 - Performance Acceleration Module (Flash Cache) (16 GB) | 10 | |||||||
1057 - Performance Acceleration Module (Flash Cache) (512 GB)* | 2 | |||||||
1058 - Performance Acceleration Module (Flash Cache) (256 GB) | - | |||||||
1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment** | 10 | |||||||
1063 - Dual-port FCoE adapter (optical) | 10 | |||||||
1064 - Dual-port FCoE adapter (cooper) | 10 | |||||||
1065 Dual-port 10 Gbps Ethernet NIC card | 10 | |||||||
Environmental specifications for N7000 series | ||||||||
Environmental specifications | ||||||||
N7900 | ||||||||
Machine Type Model | 2867-A21 | |||||||
Gateway Machine Type Model | 2867-A21 (w/FC 9551) | |||||||
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240 V ac, 11 A to 5.5 A (typical) 24 A (max.) @ 100 V ac 200 to 240 V ac, 9 A to 5.5 A (typical) 12 A (max.) @ 200 V ac |
|||||||
Thermal rating | 6142 BTU/hr. | |||||||
Weight (max.) | 242 lb (109.6 kg) | |||||||
Height | 20.8" (52.6 cm), fits into 12U space | |||||||
Width | 19" IEC rack-compliant (17.6", 44.6 cm) | |||||||
Depth | 27.4" (69.5 cm), 30.8" (78.2 cm) with cable management bracket | |||||||
Operating temperature, altitude, and relative humidity | 10C to 40C (50F to 104F); at </= 3,050 m (at </= 10,000) elevation; 20% to 80% relative humidity, noncondensing (28C wet bulb temperature) | |||||||
Nonoperating temperature and relative humidity | -40C to 65C (-40F to 149F); 10% to 95% relative humidity, noncondensing, in original container | |||||||
Operating acoustic noise | 49 dBA sound pressure (LpA) @ normal operating conditions (at 23C and at sea level) | |||||||
Min. cabinet clearances | 6" (15.3 cm) front; 12" (30.5 cm) rear | |||||||
Min. service clearances | 25" (63.5 cm) from front of cabinet; 40" (102 cm) from rear of cabinet | |||||||
Maximum altitude | 2133 m (7,000 ft.) | |||||||
Specifications for N6000 series | ||||||||
Specifications | N6040 | N6040 | N6060 | |||||
Machine type model | 2858-A10 | 2858-A20 | 2858-A22 | |||||
Gateway Machine Type Model | 2858-A10 (w/FC 9551) | 2858-A20 (w/FC 9551) |
2858-A22 (w/FC 9551) |
|||||
Controller Configuration | Single | Dual (active/active) | Dual (active/active) | |||||
Processors Speed and Type | 2.4 GHz AMD Dual-core 64-bit Opteron | |||||||
Number of Processors | 1 | 2 | 4 | |||||
Random Access Memory | 4 GB | 8 GB | 16 GB | |||||
Nonvolatile Memory | 512 MB | 1 GB | 4 GB | |||||
Integrated I/O Ports | ||||||||
Fibre Channel Ports (Speed) | 4 (4-Gbps) | 8 (4-Gbps) | 8 (4-Gbps) | |||||
Ethernet Ports (Speed) | 2 (1-Gbps) | 4 (1-Gbps) | 4 (1-Gbps) | |||||
Storage Scalability | ||||||||
Maximum Number of Fibre Channel Loops | 10 | 10 | 10 | |||||
Maximum Raw Capacity | 420 TB | 420 TB | 672 TB | |||||
Maximum Number of Disk Drives | 420 | 420 | 672 | |||||
Maximum Volume Size | 16 TB | 16 TB | 16 TB | |||||
Maximum Size of Volumes/LUNs | 2048 | 2048 | 2048 | |||||
Maximum Number of Storage Enclosures | 30 | 30 | 48 | |||||
Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) | 256 | |||||||
I/O Scalability | ||||||||
PCI-e Expansion Slots | 4 | 8 | 8 | |||||
Maximum Number FC Ports | 20 | 40 | 40 | |||||
Maximum Number of Ethernet Ports | 18 | 36 | 36 | |||||
Maximum Number of Optional Adapters | 4 | 8 | 8 | |||||
Storage Expansion Unit Disk Drive Support | ||||||||
EXN4000 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) | 4-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm 2-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm |
|||||||
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 1 TB, 2 TB |
|||||||
EXN1000 SATA disk storage expansion unit (MTM 2861-001) | SATA: 1 TB, 2 TB | |||||||
Maximum Number of Adapters Supported Per System (belownot to exceed Maximum Number of Optional Adapters) | ||||||||
1012 - Dual-Port GbE NIC (fibre) | 4 | 8 | 8 | |||||
1013 - Dual-Port GbE NIC (copper) | 4 | 8 | 8 | |||||
1014 - Dual-Port 4-Gbps FC HBA Disk | 4 | 8 | 8 | |||||
1015 - Dual-Port 4-Gbps FC HBA Tape | 4 | 8 | 8 | |||||
1017 - Dual-Port 4-Gbps FC HBA Target | 4 | 8 | 8 | |||||
1021 - Dual-Port GbE iSCSI Target (fibre) | 4 | 8 | 8 | |||||
1023 - Quad-Port GbE NIC (copper) | 4 | 8 | 8 | |||||
1024 - Dual-Port SCSI Ultra320 HBA Tape | 4 | 8 | 8 | |||||
1026 - Dual-Port GbE NIC (copper) | 4 | 8 | 8 | |||||
1029 - Quad-Port 4-Gbps FC HBA DISK | 4 | 8 | 8 | |||||
1031 - Dual-Port 10-GbE TOE NIC | 4 | 8 | 8 | |||||
1032 - Dual-Port MetroCluster VI HBA | 3 | 6 | 6 | |||||
1033 - SnapMirror Over FC HBA PCI-e | 4 | 8 | 8 | |||||
1035 - Quad-Port 4-Gbps FC HBA Tape/Disk | 4 | 8 | 8 | |||||
1036 PCIe 2 port 8 GB FC Target HBA | 4 | 8 | 8 | |||||
1056 - Performance Acceleration Module (Flash Cache) (16 GB) | 4 | 8 | 8 | |||||
1057 - Performance Acceleration Module (Flash Cache) (512 GB) | - | - | - | |||||
1058 - Performance Acceleration Module (Flash Cache) (256 GB)* | 2 | 4 | 4 | |||||
1061 Quad-port 3 Gbps SAS adapter for Disk Attachment** | 4 | 8 | 8 | |||||
1063 - Dual-port FCoE adapter (optical) | 4 | 8 | 8 | |||||
1064 - Dual-port FCoE adapter (cooper) | 4 | 8 | 8 | |||||
1065 Dual-port 10 Gbps Ethernet NIC card | 4 | 8 | 8 | |||||
Specifications | N6070 | |||||||
Machine Type Model | 2858-A21 | |||||||
Gateway Machine Type Model | 2858-A21 (w/FC 9551) |
|||||||
Controller Configuration | Dual (active/active) | |||||||
Processors Speed and Type | 2.4 GHz AMD Dual-core 64-bit Opteron | |||||||
Number of Processors | 4 | |||||||
Random Access Memory | 32 GB | |||||||
Nonvolatile Memory | 4 GB | |||||||
Integrated I/O Ports | ||||||||
Fibre Channel Ports (Speed) | 8 (4-Gbps) | |||||||
Ethernet ports (Speed) | 4 (1-Gbps) | |||||||
Storage Scalability | ||||||||
Maximum Number of Fibre Channel Loops | 10 | |||||||
Maximum Raw Capacity | 840 TB | |||||||
Maximum Number of Disk Drives | 840 | |||||||
Maximum Volume Size | 16 TB | |||||||
Maximum Size of Volumes/LUNs | 2048 | |||||||
Maximum Number of Storage Enclosures | 60 | |||||||
Maximum Number of FC or iSCSI SAN connected servers (per controller and per active/active configuration) | 256 | |||||||
I/O Scalability | ||||||||
PCI-e Expansion Slots | 8 | |||||||
Maximum Number FC Ports | 40 | |||||||
Maximum Number of Ethernet Ports | 36 | |||||||
Maximum Number of Optional Adapters | 8 | |||||||
Storage Expansion Unit Disk Drive Support | ||||||||
EXN4000 4-Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) | 4-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm 2-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm |
|||||||
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 1 TB, 2 TB |
|||||||
EXN1000 SATA disk storage expansion unit (MTM 2861-001) | SATA: 1 TB, 2 TB | |||||||
Maximum Number of Adapters Supported Per System (belownot to exceed Maximum Number of Optional Adapters) | ||||||||
1012 - Dual-Port GbE NIC (fibre) | 8 | |||||||
1013 - Dual-Port GbE NIC (copper) | 8 | |||||||
1014 - Dual-Port 4-Gbps FC HBA Disk | 8 | |||||||
1015 - Dual-Port 4-Gbps FC HBA Tape | 8 | |||||||
1017 - Dual-Port 4-Gbps FC HBA Target | 8 | |||||||
1021 - Dual-Port GbE iSCSI Target (fibre) | 8 | |||||||
1023 - Quad-Port GbE NIC (copper) | 8 | |||||||
1024 - Dual-Port SCSI Ultra320 HBA Tape | 8 | |||||||
1026 - Dual-Port GbE NIC (copper) | 8 | |||||||
1029 - Quad-Port 4-Gbps FC HBA DISK | 8 | |||||||
1031 - Dual-Port 10-GbE TOE NIC | 8 | |||||||
1032 - Dual-Port MetroCluster VI HBA | 6 | |||||||
1033 - SnapMirror Over FC HBA PCI-e | 8 | |||||||
1035 - Quad-Port 4-Gbps FC HBA Tape/Disk | 8 | |||||||
1036 - PCIe 2 port 8 GB FC Target HBA | 8 | |||||||
1056 - Performance Acceleration Module (Flash Cache) (16 GB) | 8 | |||||||
1057 - Performance Acceleration Module (Flash Cache) (512 GB) | 4 | |||||||
1058 - Performance Acceleration Module (Flash Cache) (256 GB) | - | |||||||
1061 - Quad-port 3 Gbps SAS adapter for Disk Attachment | 8 | |||||||
1063 - Dual-port FCoE adapter (optical) | 8 | |||||||
1064 - Dual-port FCoE adapter (cooper) | 8 | |||||||
1065 Dual-port 10 Gbps Ethernet NIC card | 8 | |||||||
Environmental specifications and regulations for N6000 series | Environmental specifications | N6040 | N6040 | N6060 | ||||
Machine Type Model | 2858-A10 | 2858-A20 | 2858-A22 | |||||
Gateway Machine Type Model | 2858-A10 (w/FC 9551) |
2858-A20 (w/FC 9551) |
2858-A22 (w/FC 9551) |
|||||
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 3.8 A @ 100 - 120 V ac (typical) | 2 A @ 200 - 240 V ac (typical) | 6 A @ 100 - 120 V ac (typical) | |||||
Thermal rating | 1405 BTU/hr. (max) | 2714 BTU/hr. (max) | 3574 BTU/hr. (max) | |||||
Weight (max.) | 102 lb (46.2 kg) | 121 lb (54.9 kg) | 121 lb (54.9 kg) | |||||
Height | 10.2" (25.9 cm), fits into 6U space | |||||||
Width | 19" IEC rack-compliant (17.6", 44.7 cm) | |||||||
Depth | 24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket | |||||||
Operating temperature, altitude, and relative humidity | 10C to 40C (50F to 104F); at </= 3,050 m (at </= 10,000) elevation; 20% to 80% relative humidity, noncondensing (28C wet bulb temperature) | |||||||
Nonoperating temperature and relative humidity | -40C to 65C (-40F to 149F); 10% to 95% relative humidity, noncondensing, in original container | |||||||
Operating acoustic noise | 56 dBA sound pressure (LpA) @ normal operating conditions (at 23C and at sea level) | |||||||
Min. cabinet clearances | 10" (25.4 cm) front; 12" (30.5 cm) rear | |||||||
Min. service clearances | 30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet | |||||||
Maximum altitude | 3050 m (10,000 ft.) | |||||||
Environmental specifications | N6070 | |||||||
Machine Type Model | 2858-A21 | |||||||
Gateway Machine Type Model | 2858-A11 (w/FC 9551) |
|||||||
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) | 100 to 240 V ac, 12 A to 8 A (max) | |||||||
8.1 A @ 100 - 120 V ac (typical) 4 A @ 200 - 240 V ac (typical) |
||||||||
Thermal rating | 3574 BTU/hr. (max) | |||||||
Weight (max.) | 121 lb (54.9 kg) | |||||||
Height | 10.2" (25.9 cm), fits into 6U space | |||||||
Width | 19" IEC rack-compliant (17.6", 44.7 cm) | |||||||
Depth | 24.3" (61.7 cm), 28.1" (71.3 cm) with cable management bracket | |||||||
Operating temperature, altitude, and relative humidity | 10C to 40C (50F to 104F); at </= 3,050 m (at </= 10,000) elevation; 20% to 80% relative humidity, noncondensing (28C wet bulb temperature) | |||||||
Nonoperating temperature and relative humidity | -40C to 65C (-40F to 149F); 10% to 95% relative humidity, noncondensing, in original container | |||||||
Operating acoustic noise | 56 dBA sound pressure (LpA) @ normal operating conditions (at 23C and at sea level) | |||||||
Min. cabinet clearances | 10" (25.4 cm) front; 12" (30.5 cm) rear | |||||||
Min. service clearances | 30" (76.2 cm) from front of cabinet; 30" (76.2 cm) from rear of cabinet | |||||||
Maximum altitude | 3050 m (10,000 ft.) | |||||||
Regulations | ||||||||
Filer safety | EN 60950:2002, CE, CSA 60950 and NRTL (UL) CB (all national deviations), EN60825-1:1994, IRAM, GOST-R | |||||||
Disk shelf safety | UL/C-UL; CE | |||||||
Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI | |||||||
Immunity | EN 55024:1998 | |||||||
Storage subsystem support specifications | ||||||||
Storage interface/data rate | PCI-Based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4 Gbps | |||||||
Storage arrays | Refer to the interoperability matrix for the latest list of storage systems supported at: ibm.com/systems/storage/network/interophome.html | |||||||
Storage Expansion Unit Disk Drive Support | ||||||||
EXN4000 - 4 Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) | 4-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm 2-Gbps Fibre Channel: 300 GB, 450 GB, 600 GB, 15,000 rpm |
|||||||
EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) | SAS: 300 GB, 450 GB, 600 GB, 15,000 rpm SATA: 1 TB, 2 TB |
|||||||
EXN1000 SATA disk storage expansion unit (MTM 2861-001) | SATA: 1 TB, 2 TB | |||||||
Storage Expansion Unit Specifications | ||||||||
Disk storage expansion units supported | EXN4000 - 4 Gbps Fibre Channel Disk Storage Expansion Unit (MTM 2863-004) EXN3000 - SAS Disk Storage Expansion Unit (MTM 2857-003) EXN1000 SATA disk storage expansion unit (MTM 2861-001) Each with 14 low-profile slots for fibre channel and SATA disk drives Legacy Support for Expansion Unit |
|||||||
Disk drive storage shelf interface | PCI-x or PCI-e-based Fibre Channel-Arbitrated Loop (FC-AL) | |||||||
Environmental specifications | ||||||||
Power supply/cooling fans | Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220 V/110 V) | |||||||
AC power/max. current | 100 to 120 V ac/4.4 A; 200 to 240 V ac/2.3 A 100 to 120 V ac/7 A; 200 - 240 V ac/3.5 A; 50/60 Hz | |||||||
Operating temperature maximum range | 10C to 40C (50F to 104F) | |||||||
Recommended operating temperature range | 20C to 25C (68F to 77F) | |||||||
Operating relative humidity range | 10% to 95% relative humidity, noncondensing 10% to 95% | |||||||
Recommended operating relative humidity range | 40% to 55% noncondensing | |||||||
Nonoperating temperature range | -40C to 65C (-40F to 149F) | |||||||
Nonoperating relative humidity range | 10% to 95% relative humidity, noncondensing | |||||||
Thermal rating | 1,215 Btu/hr (fully loaded disk storage expansion unit) | |||||||
Operating acoustic noise | 56.4 dBA @ 1 m at 23C, 5.64 bels @ 23C | |||||||
Dimensions (height/width/depth) | EXN4000 and EXN1000 3U EIA (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.8 cm) EXN3000 4U EIA (6.9", 17.49 cm)/19" IEC rack-compliant (17.7", 44.87 cm)/25.7" (65.35 cm) |
|||||||
Weight | EXN4000 - 35.8 kg (78.8 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty EXN3000 - 110 lb (49.9 kg) fully loaded with disk drives, 53.7 lbs (24.4 kb) empty EXN1000 - 35 kg (77 lbs) fully loaded with disk drives, 23 kg (50.6 lbs) empty |
|||||||
Regulations | ||||||||
Disk shelf safety | UL/C-UL; CE | |||||||
Emissions | FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI | |||||||
Immunity | EN 55024:1998 | |||||||
For N series tape drive support (refer to interoperability matrix on IBM Web site) | ||||||||
N series Gateway supported backup methods | ||||||||
Disk-based backup | SnapVault, SnapMirror | |||||||
Host-based backup | NDMP/NFS/CIFS/iSCSI | |||||||
GbE-attached tape support | ibm.com/systems/storage/network, refer to System Storage N series interoperability matrix | |||||||
Direct-attached tape support | ibm.com/systems/storage/network, refer to System Storage N series interoperability matrix | |||||||
SAN-attached tape support | ibm.com/systems/storage/network, refer to System Storage N series interoperability matrix | |||||||
iSCSI initiator, IP fabric and host-attached support | ibm.com/systems/storage/network, refer to System Storage N series interoperability matrix |
Corequisite: Performance Acceleration Module II software feature per filer/gateway. Requires ONTAP 7.3.2
** For use with the EXN3000 and QSFP-QSFP cabling